What is EN ISO 25539-1:2015+A1:2017

EN ISO 25539-1:2015+A1:2017 is an international standard that specifies the requirements for cardiovascular implants - endovascular devices. This standard provides guidance and criteria for the design, manufacturing, and testing of these devices. It ensures that the endovascular devices comply with the necessary safety and performance standards to minimize risks to patients. In this technical article, we will explore the key aspects of EN ISO 25539-1:2015+A1:2017 and its importance in the field of cardiovascular implants.

The Scope of EN ISO 25539-1:2015+A1:2017

The scope of EN ISO 25539-1:2015+A1:2017 covers a wide range of endovascular devices used in the treatment of cardiovascular diseases. These devices include stents, stent-grafts, balloons, vena cava filters, vascular grafts, and more. The standard specifies requirements for both implantable and non-implantable devices, as well as their delivery systems. It also details the performance and biocompatibility requirements that these devices must meet before they can be considered safe and effective for use.

The Design and Manufacturing Requirements

One of the key aspects of EN ISO 25539-1:2015+A1:2017 is the design and manufacturing requirements outlined in the standard. These requirements ensure that the endovascular devices are designed and manufactured in a way that minimizes potential hazards to patients. The standard specifies various factors such as material selection, dimensions, labeling, packaging, and sterility assurance. Manufacturers must comply with these requirements to maintain the quality and integrity of the endovascular devices throughout the manufacturing process.

Testing and Validation Processes

EN ISO 25539-1:2015+A1:2017 also emphasizes the importance of testing and validation processes for endovascular devices. The standard provides guidance on the required mechanical, chemical, and biological testing that these devices must undergo before they can be approved for use. These tests evaluate the device's performance under different conditions, its resistance to fatigue, its biocompatibility, and its ability to withstand various physiological forces. By following these testing and validation procedures, manufacturers can ensure that their endovascular devices meet the necessary safety and performance standards.

CATEGORIES

CONTACT US

Contact: Nina She

Phone: +86-13751010017

E-mail: sales@china-gauges.com

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

Scan the qr codeclose
the qr code